kelvinsmalllogo.jpg (2664 bytes)

Industrial Thermostats

Table of Contents

caloritech.gif (3121 bytes)

Type AR thermostats are for use in general purpose industrial applications where close control of process temperatures is not a requirement. The sensing bulb should never be directly immersed in corrosive liquids, lead, tin, or stereotype metals, where a protective well must be used. For open-top tanks operating up to 100 oC ( 212 oF ), the bulb and capillary can be encased in PVC sleeving.

Catalog Number Superceded Cat. No. Temp. oF Range oC Bulb Size ( ins.)
277 VAC 25 Amp D.P.S.T. - Open On Rise
AR0464 TCR220-22 0-100 (-18)-40 3/8 x 5 5/8
AR1264 TCR220-25 50-250 10-120 3/8 x 3 3/8
AR1269 - 50-250 10-120 3/16 x 10 1/4
AR2864 TCR220-28 150-550 70-280 3/8 x 3 3/8
AR2869 - 150-550 70-280 3/16 x 11 1/4
AR3769 TCR220-29 300-700 160-370 3/16 x 8 3/4
600 VAC 15 Amp T.P.S.T. - Open On Rise
AR046843 TCR630-22 0-100 (-18)-40 3/8 x 5 1/4
AR126893 TCR630-25 50-250 10-120 3/16 x 10 1/4
AR286893 TCR630-28 150-550 70-280 3/16 x 11 1/4
AR376893 TCR630-29 300-700 160-370 3/16 x 8 3/4

thermostats.jpg (25436 bytes)

SENSOR MATERIALS - AR3769 and AR 376893 have stainless steel bulb and capillaries, all other units are nickel plated copper.

 


Industrial HIGH LIMITS

Type ARC thermal cutouts are recommended for use in industrial processes where control malfunction, loss of liquid level, or air flow may cause a safety hazard or could result in damage to the heater. Controls have a screwdriver adjustement to prevent tampering. If limit temperature is reached the contacts will open and remain open until the temperature has dropped below the control setting and the control reset button is activated.

Cat.No.

Open On Rise

Superceded Cat.No. Temp oF Range oC Bulb Size Ni-Plated Copper
ARC260 HL426 110-500 40-260 3/8 x 3"
ARC340 HL1234 250-650 120-340 3/8 x 3"