kelvinsmalllogo.jpg (2664 bytes)

Ratings

Table of Contents

RATINGS ARE IN AMPS UNLESS OTHERWISE SPECIFIED

Type of Loads 30NO 35NO 35NO (H) 35NC 60NO 60NO (H) 60NC 100NO 100NO (H) 100NC
AC RESISTIVE 240V 30 35 35 35 60 60 60 100 100 100
480V 30 35 35 35 60 60 60 80 80
600V 30 35 -- -- 48 -- -- 70 70
A.C. IND. P.F. .4 or greater 120V -- -- 25 25 -- 30 30 -- 100
240V -- -- 15 15 -- 20 20 -- 100
General Purpose P.F. .7 or greater 240V -- -- 35 35 -- 60 60 -- 100 80
480V 80
D.C. Resistive Heating 48V -- -- 35 35 -- 60 60 -- 100
125V -- -- 16 16 -- 40 40 -- 50
250V -- -- 12 12 -- 20 20 -- 30
Tungsten Lamp 120V 30 35 35 60 60 100 100
Motor Loads Single Phase 120V -- 1 HP 2 HP -- 3 HP -- 7.5 HP
240V -- 1 HP 3 HP -- 5 HP -- 10 HP
Three Phase 240V -- -- 5 HP -- 7.5 HP -- 15 HP
480V -- -- 7.5 HP -- 10 HP -- 20 HP

KEY:

WB00941_.GIF (1211 bytes)    Blue area for UL listings and/or component recognition.

--        Not recommended for this type of load.