LOW DENSITY CARTRIDGE HEATERS |
APPLICATIONS
Where watt densities of less than 45 watts/square inch can be used
EXAMPLES
Including but not limited to Dies, Heat Sealing, Labeling, Packaging, and Molding
CHARACTERISTICS
STANDARD LEAD CONFIGURATION |
|
| Internally connected leads with 12" of fiberglass lead wire. | |
| Tin plated copper braid protects fiberglass leads from abrasion. The braid is silver soldered in place. | |
![]() |
Galvanized conduit protects fiberglass leads from sharp objects. The hose is silver soldered in place. |
![]() |
High temperature beads cover internally connected pins. |
![]() |
Right angle hose protects leads from sharp objects or small amounts of contaminants in area where space is limited. |
![]() |
Right angle braid offers lead flexibility and abrasion protection where space is limited. |
![]() |
Post terminals are designed for applications requiring a fast connection using leads, spade terminals, or bus bars. 1/2", 5/8", and 3/4" diameters available |
Consult Kelvin for other available lead configurations.
TOLERANCES
Wattage: +5%, -10%
Diameter: +0.000", - 0.009"
Minimum Length: 2"
Maximum Length: 40" (longer lengths-consult Kelvin)
Length: +/- 1/16" 4" and under +/-1/8" over 4"
Wattages below 240Watts are not available at 440Volts or 480Volts
3/8" and 1/2" diameter by 2" long available at 120Volts only
Consult Kelvin for wattages that exceed recommendations.